Abstract: This Paper introduces module of conventional track and hold circuit, differential track and hold circuit and two stage track and hold circuit using Microwind 3.1 VLSI Backnend Software. A very fast and linear T & H circuit is the key element in any modern wideband data acquisition system. Applications like a cable-TV or a broad variety of different radio standards require high processing speeds with high resolution. The results came from the proposed module shows the circuit made in 32nm technology consumed less power which is 9.083 uW for conventional track and hold circuit. 5.107 uW for Differential track and hold circuit and 76.30 uW .
Keywords: Track and Hold circuit, low power consumption, low chip area, sampling switch.